11:1 Pipe Flow - Irregular Section Conduits and Type I, II and III Problems
Overview
Derek Elsworth explains how to solve pipe-flow problems with Bernoulli’s equation, Moody-chart friction factors, and hydraulic diameter for noncircular ducts. He distinguishes Type I problems, where known velocity gives a direct solution, from Type II flow-rate calculations and Type III pipe-sizing problems, which require iteration because diameter affects several terms; examples use a 1 cm pipe and discuss pipelines and salt-cavern storage for natural gas and hydrogen.
Key takeaways
- For irregular ducts, hydraulic diameter D_h = 4A/P allows standard pipe-flow equations to be applied using the conduit’s cross-sectional area and wetted perimeter.
- In a 1 cm water pipe, Reynolds number is approximately 10⁴ times velocity in m/s, making 0.1 m/s laminar at Re ≈ 1,000 and 1 m/s turbulent at Re ≈ 10,000.
- With fixed friction factor, turbulent head loss scales approximately as V², whereas substituting the laminar relation f = 64/Re makes circular-pipe head loss scale linearly with V.
- Type II flow-rate calculations require iteration: estimate friction factor, calculate velocity, infer Reynolds number, update friction factor from the Moody chart, and repeat.
- Type III pipe sizing is more coupled because diameter affects L/D, Reynolds number, and relative roughness ε/D, as well as the friction factor derived from those quantities.
- Salt caverns can store natural gas or hydrogen for later use by injecting brine to displace the gas; hydrogen storage is especially useful as an energy carrier but raises containment concerns because hydrogen can embrittle steel and escape through small openings.
Chapters
- The course moves from pipe-flow examples to networks in series, parallel, and branching configurations, then to external and open-channel flows.
- Pipeline examples include moving Marcellus Shale gas across the Northeast and transporting Canadian heavy oil to Gulf Coast refineries.
- Salt caverns can store natural gas and hydrogen; brine pumped into a cavern displaces the stored gas for delivery when demand rises.
- Hydrogen has high energy per kilogram but is difficult to contain because it can embrittle steel and escape through small openings; salt formations provide tight storage.
- Bernoulli’s equation balances upstream and downstream energy, pump head added to the system, and head losses from fittings and pipe friction.
- Minor losses from fittings use loss coefficients, while major losses accumulate through the friction factor multiplied by pipe length over diameter.
- For a large tank connected by a pipe, free-surface velocities and gauge pressures can be treated as zero, simplifying the energy balance.
- The Moody chart uses Reynolds number and relative roughness: laminar friction depends on Reynolds number, while fully turbulent friction becomes primarily dependent on relative roughness.
- For a noncircular conduit, use hydraulic diameter D_h = 4A/P, where A is cross-sectional area and P is wetted perimeter.
- For a circular pipe, substituting A = πD²/4 and P = πD reduces the hydraulic diameter to the ordinary diameter D.
- Use hydraulic diameter in Reynolds number, relative roughness, and the length-to-diameter term in the friction-loss equation.
- For laminar flow, tabulated friction-factor relations cover shapes such as annuli and rectangular ducts; parallel-plate flow also relates to fractured-rock permeability, k = B³/(12S).
- Type I problems provide velocity or flow rate and pipe geometry, allowing Reynolds number, friction factor, and head loss to be calculated in sequence.
- Type II problems provide geometry and pressure or head loss but ask for flow rate, so velocity and friction factor must be found consistently.
- Type III problems ask for pipe diameter or another geometric dimension needed to deliver a specified flow under a known pressure or pump head.
- Type II and III solutions generally require iteration because the unknown velocity or diameter affects Reynolds number and friction factor.
- For a 1 cm diameter, 1 m long water pipe, Reynolds number is approximately velocity multiplied by 10⁴ when velocity is in m/s.
- At 0.1 m/s, Reynolds number is 1,000, within the laminar regime; using f = 64/Re gives a head loss of about 3.32 × 10⁻⁴ m.
- At 1 m/s, Reynolds number is 10,000; the smooth-pipe friction factor is about 0.03, while relative roughness ε/D = 0.01 gives a larger value near 0.043.
- With the rough-pipe friction factor near 0.043, the 1 m pipe’s head loss is about 0.2 m, calculated directly because velocity is specified.
- The Darcy-Weisbach head-loss relation is h_L = f(L/D)(V²/2g), with friction factor f determined by flow regime and roughness.
- In turbulent flow, friction factor is treated as fixed for a given operating condition, so head loss scales approximately with velocity squared.
- For laminar flow in a circular pipe, substituting f = 64/Re makes head loss proportional to velocity rather than velocity squared.
- The different scaling means doubling flow velocity approximately doubles laminar head loss but can increase turbulent head loss by roughly a factor of four.
- The example specifies a 1 cm pipe, 1 m length, 0.1 m head loss, and relative roughness ε/D = 0.01, but leaves velocity unknown.
- Rearranging the Darcy-Weisbach equation gives velocity as a function of head loss, pipe dimensions, gravity, and the assumed friction factor.
- An initial turbulent friction-factor estimate near 0.038 gives a velocity estimate around 0.7 m/s.
- The estimated velocity determines Reynolds number, which can then be checked against the Moody chart to update the friction factor.
- An initial velocity of 0.7 m/s implies Reynolds number near 7,000 for the 1 cm water pipe and a chart friction factor around 0.042.
- Using the updated friction factor gives a velocity near 0.66 m/s, which implies Reynolds number around 6,600.
- A further Moody-chart estimate near f = 0.045 refines the velocity; repeat the calculation until successive values change only slightly.
- The example lies near transitional flow, where friction factor depends on both Reynolds number and relative roughness, unlike the simpler laminar and fully turbulent limits.
- A Type III problem determines the pipe diameter needed to deliver a target flow rate under a specified pressure drop or pump head.
- Diameter appears in relative roughness ε/D, Reynolds number, and the major-loss ratio L/D, so changing diameter changes multiple parts of the calculation.
- Because the friction factor also depends on Reynolds number and relative roughness, pipe sizing is more coupled than the Type II velocity calculation.
- The follow-up Wednesday material continues the Type III sizing method and examples.
Transcript excerpt
0:25 All right. >> [sighs]
1:24 >> Well, why not get going? Thanks for coming out. Hopefully Oh, it's recording. Yeah. I won't say how many are here. Could turn the camera on you. So, thanks for coming out. We'll carry on. It'll be a short week for me and for you in this course. Just today. And [clears throat] I'll ask you to look at the other two online on Wednesday and Friday. I think Wednesday will be a bit of a repeat of what we'll talk about today. We'll go through some examples today on pipe flow. So, this week is the our last chance to look at pipe flow. We spent last week doing the the basics and going through some examples on Friday. Um I briefly talked about type the imaginatively labeled type one, type two, and type three problems for solving
2:11 pipe flow problems. We'll talk about those today in broad view, and then Friday will be pipe networks. So, pipes in series uh a bit like we talked about for the uh the jet lab with the uh the solution that we did on Friday, but also pipes in parallel and branching networks. And so, that'll be the final thing that we cover on Friday. Then next week uh following week is um external flows. Um we already said that they follow the same kind of format to the Moody diagrams. We calculate for a given Reynolds number an Euler number. Um that Euler number is called a drag coefficient or a lift coefficient when we talk about external flows. So, we can
3:00 calculate not the flow around or in uh systems, but the forces that are exerted on systems. Um we're doing the same for pipe flow. When water flows through a pipe or a
This is the start of the transcript. Save this video free for the whole transcript, searchable and time-coded.
In this course
Related notes
Summary, takeaways, and chapters were generated by AI from the video's transcript and may contain errors. The video belongs to its creator, Derek Elsworth.